Understanding ASME PTC 4.1 – The Standard for Steam Generator Efficiency Testing
ASME PTC 4.1 provides a comprehensive framework for performance testing of coal-fired steam generating units. The standard covers the following topics: Asme Ptc 4.1.pdf
| Parameter | Required Accuracy | Instrument | |-----------|------------------|------------| | Fuel flow | ±1% | Belt scale, Coriolis, orifice | | Steam flow | ±0.5% | ASME nozzle, Venturi | | Feedwater temp | ±0.5°F | RTD | | Flue gas O₂ | ±0.2% | Zirconia or paramagnetic | | Flue gas CO | ±5 ppm | NDIR | | Flue gas temp | ±2°F | Type K thermocouple (traverse) | | Ambient dry/wet bulb | ±0.5°F | Psychrometer | Understanding ASME PTC 4
Understanding ASME PTC 4.1 – The Standard for Steam Generator Efficiency Testing
ASME PTC 4.1 provides a comprehensive framework for performance testing of coal-fired steam generating units. The standard covers the following topics:
| Parameter | Required Accuracy | Instrument | |-----------|------------------|------------| | Fuel flow | ±1% | Belt scale, Coriolis, orifice | | Steam flow | ±0.5% | ASME nozzle, Venturi | | Feedwater temp | ±0.5°F | RTD | | Flue gas O₂ | ±0.2% | Zirconia or paramagnetic | | Flue gas CO | ±5 ppm | NDIR | | Flue gas temp | ±2°F | Type K thermocouple (traverse) | | Ambient dry/wet bulb | ±0.5°F | Psychrometer |